Skip to content Skip to navigation

PENNINGVAC PTR 90 RNS - DN 40 KF

Part Number: 23L0131100
GBP 1,544.00

Variant

Explore the range of variants given below to compare the product

Short Description Part Number Connection Vacuum Inlet Flange Dimension Length Weight Communication Interface Protocol Communication Interfaces Customer Connection electrical comms interface connector Variant Gauges
23L0020200 DN 25 ISO-KF (NW25) 0.092 0.350 Gauge RS485 digital protocol RS485 (serial) DSUB 9-PIN - Male PTR 90 RN (digital output)
23L0021100 DN 25 ISO-KF (NW25) 0.092 0.350 1.4 - 8.6 V log linear with pressure PTR 90 RN 0-10 V (analog output - linear) RJ45 (FCC 68) - Female PTR 90 RN (linear 0-10V output)
23L0021120 DN 25 ISO-KF (NW25) 0.092 0.350 Matched wide range gauge (1.4 to 8.6 V Inficon & Pfeiffer from 1x10-9 to 1x103 log linear with pressure (G)) MPG500/504/400/401 & PKR360/361/251/261 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0021140 DN 25 ISO-KF (NW25) 0.092 0.350 Matched wide range gauge (1.5 to 6.9375 V MKS972 from 1x10-8 to 1x103 log linear with pressure (Q)) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0025200 DN 25 ISO-KF (NW25) 0.092 0.350 Gauge RS232 digital protocol RS232 (serial) DSUB 9-PIN - Male PTR 90 RN (digital output)
23L0030200 DN 40 ISO-KF (NW40) 0.092 0.380 Gauge RS485 digital protocol RS485 (serial) DSUB 9-PIN - Male PTR 90 RN (digital output)
23L0031100 DN 40 ISO-KF (NW40) 0.092 0.380 1.4 - 8.6 V log linear with pressure PTR 90 RN 0-10 V (analog output - linear) RJ45 (FCC 68) - Female PTR 90 RN (linear 0-10V output)
23L0031120 DN 40 ISO-KF (NW40) 0.092 0.380 Matched wide range gauge (1.4 to 8.6 V Inficon & Pfeiffer from 1x10-9 to 1x103 log linear with pressure (G)) MPG500/504/400/401 & PKR360/361/251/261 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0031140 DN 40 ISO-KF (NW40) 0.092 0.380 Matched wide range gauge (1.5 to 6.9375 V MKS972 from 1x10-8 to 1x103 log linear with pressure (Q)) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0035200 DN 40 ISO-KF (NW40) 0.092 0.380 Gauge RS232 digital protocol RS232 (serial) DSUB 9-PIN - Male PTR 90 RN (digital output)
23L0040200 DN 40 CF (2.75") 0.098 0.630 Gauge RS485 digital protocol RS485 (serial) DSUB 9-PIN - Male PTR 90 RN (digital output)
23L0041100 DN 40 CF (2.75") 0.098 0.630 1.4 - 8.6 V log linear with pressure PTR 90 RN 0-10 V (analog output - linear) RJ45 (FCC 68) - Female PTR 90 RN (linear 0-10V output)
23L0041120 DN 40 CF (2.75") 0.098 0.630 Matched wide range gauge (1.4 to 8.6 V Inficon & Pfeiffer from 1x10-9 to 1x103 log linear with pressure (G)) MPG500/504/400/401 & PKR360/361/251/261 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0041140 DN 40 CF (2.75") 0.098 0.630 Matched wide range gauge (1.5 to 6.9375 V MKS972 from 1x10-8 to 1x103 log linear with pressure (Q)) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0045200 DN 40 CF (2.75") 0.098 0.630 Gauge RS232 digital protocol RS232 (serial) DSUB 9-PIN - Male PTR 90 RN (digital output)
23L0120200 DN 25 ISO-KF (NW25) 0.092 0.350 Gauge RS485 digital protocol RS485 (serial) DSUB 9-PIN - Male PTR 90 RN (digital output, setpoint)
23L0121100 DN 25 ISO-KF (NW25) 0.092 0.350 1.4 - 8.6 V log linear with pressure PTR 90 RN 0-10 V (analog output - linear) RJ45 (FCC 68) - Female PTR 90 RNS (linear 0-10V output, setpoint)
23L0121120 DN 25 ISO-KF (NW25) 0.092 0.350 Matched wide range gauge (1.4 to 8.6 V Inficon & Pfeiffer from 1x10-9 to 1x103 log linear with pressure (G)) MPG500/504/400/401 & PKR360/361/251/261 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0121140 DN 25 ISO-KF (NW25) 0.092 0.350 Matched wide range gauge (1.5 to 6.9375 V MKS972 from 1x10-8 to 1x103 log linear with pressure (Q)) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0121200 DN 25 ISO-KF (NW25) 0.092 0.350 1.4 - 8.6 V log linear with pressure PTR 90 RN 0-10 V (analog output - linear) DSUB 9-PIN - Male PTR 90 RNS (linear 0-10V output, setpoint)
23L0121220 DN 25 ISO-KF (NW25) 0.092 0.350 Matched wide range gauge (1.4 to 8.6 V Inficon & Pfeiffer from 1x10-9 to 1x103 log linear with pressure (G)) MPG500/504/400/401 & PKR360/361/251/261 0-10 V (analog output - matched output) DSUB 9-PIN - Male PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0121240 DN 25 ISO-KF (NW25) 0.092 0.350 Matched wide range gauge (1.5 to 6.9375 V MKS972 from 1x10-8 to 1x103 log linear with pressure (Q)) 0-10 V (analog output - matched output) DSUB 9-PIN - Male PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0125200 DN 25 ISO-KF (NW25) 0.092 0.350 Gauge RS232 digital protocol RS232 (serial) DSUB 9-PIN - Male PTR 90 RN (digital output, setpoint)
23L0130200 DN 40 ISO-KF (NW40) 0.092 0.380 Gauge RS485 digital protocol RS485 (serial) DSUB 9-PIN - Male PTR 90 RN (digital output, setpoint)
23L0131100 DN 40 ISO-KF (NW40) 0.092 0.380 1.4 - 8.6 V log linear with pressure PTR 90 RN 0-10 V (analog output - linear) RJ45 (FCC 68) - Female PTR 90 RNS (linear 0-10V output, setpoint)
23L0131120 DN 40 ISO-KF (NW40) 0.092 0.380 Matched wide range gauge (1.4 to 8.6 V Inficon & Pfeiffer from 1x10-9 to 1x103 log linear with pressure (G)) MPG500/504/400/401 & PKR360/361/251/261 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0131140 DN 40 ISO-KF (NW40) 0.092 0.380 Matched wide range gauge (1.5 to 6.9375 V MKS972 from 1x10-8 to 1x103 log linear with pressure (Q)) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0131200 DN 40 ISO-KF (NW40) 0.092 0.380 1.4 - 8.6 V log linear with pressure PTR 90 RN 0-10 V (analog output - linear) DSUB 9-PIN - Male PTR 90 RNS (linear 0-10V output, setpoint)
23L0131220 DN 40 ISO-KF (NW40) 0.092 0.380 Matched wide range gauge (1.4 to 8.6 V Inficon & Pfeiffer from 1x10-9 to 1x103 log linear with pressure (G)) MPG500/504/400/401 & PKR360/361/251/261 0-10 V (analog output - matched output) DSUB 9-PIN - Male PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0131240 DN 40 ISO-KF (NW40) 0.092 0.380 Matched wide range gauge (1.5 to 6.9375 V MKS972 from 1x10-8 to 1x103 log linear with pressure (Q)) 0-10 V (analog output - matched output) DSUB 9-PIN - Male PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0135200 DN 40 ISO-KF (NW40) 0.092 0.380 Gauge RS232 digital protocol RS232 (serial) DSUB 9-PIN - Male PTR 90 RN (digital output, setpoint)
23L0140200 DN 40 CF (2.75") 0.098 0.630 Gauge RS485 digital protocol RS485 (serial) DSUB 9-PIN - Male PTR 90 RN (digital output, setpoint)
23L0141100 DN 40 CF (2.75") 0.098 0.630 1.4 - 8.6 V log linear with pressure PTR 90 RN 0-10 V (analog output - linear) RJ45 (FCC 68) - Female PTR 90 RNS (linear 0-10V output, setpoint)
23L0141120 DN 40 CF (2.75") 0.098 0.630 Matched wide range gauge (1.4 to 8.6 V Inficon & Pfeiffer from 1x10-9 to 1x103 log linear with pressure (G)) MPG500/504/400/401 & PKR360/361/251/261 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0141140 DN 40 CF (2.75") 0.098 0.630 Matched wide range gauge (1.5 to 6.9375 V MKS972 from 1x10-8 to 1x103 log linear with pressure (Q)) 0-10 V (analog output - matched output) RJ45 (FCC 68) - Female PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0141200 DN 40 CF (2.75") 0.098 0.630 Matched wide range gauge (1.5 to 6.9375 V MKS972 from 1x10-8 to 1x103 log linear with pressure (Q)) 0-10 V (analog output - linear) DSUB 9-PIN - Male PTR 90 RNS (linear 0-10V output, setpoint)
23L0141220 DN 40 CF (2.75") 0.098 0.630 Matched wide range gauge (1.4 to 8.6 V Inficon & Pfeiffer from 1x10-9 to 1x103 log linear with pressure (G)) MPG500/504/400/401 & PKR360/361/251/261 0-10 V (analog output - matched output) DSUB 9-PIN - Male PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0141240 DN 40 CF (2.75") 0.098 0.630 Matched wide range gauge (1.5 to 6.9375 V MKS972 from 1x10-8 to 1x103 log linear with pressure (Q)) 0-10 V (analog output - matched output) DSUB 9-PIN - Male PTR 90 RN(S) G/Q (Matched to competitor standard output, linear 0-10V output, (setpoint))
23L0145200 DN 40 CF (2.75") 0.098 0.630 Gauge RS232 digital protocol RS232 (serial) DSUB 9-PIN - Male PTR 90 RN (digital output, setpoint)

PENNINGVAC PTR

PENNINGVAC PTR - Leybold Vacuum is proud to introduce its latest update of the cold-cathode gauge technology. With the PTR 90 RN wide range and PTR 225 RN pure cold cathode you get the latest technology fitting within the same family characteristics as our latest pirani gauge TTR 91 RN.

Features and Benefits

  • Easy monitoring and control
  • Robust
  • Flexibility
  • Easy serviceability
  • In-house manufacturing from the expert
  • 2 interfaces to choose from
  • Reduced footprint
  • Compatibility
  • Adaptive led pressure indication
  • Wide range power supply

General Product Information

Connection Vacuum Inlet Flange DN 40 ISO-KF (NW40)
Dimension Height 0.045
Dimension Length 0.092
Dimension Width 0.045
IP Rating IP40
Supply Frequency DC Voltage
Supply Voltage DC 15-48V
Weight 0.380
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.

Classification

Product Pressure Range High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
Medium Vacuum: 1 mbar - 1·10⁻³ mbar
Rough Vacuum: 1000 mbar - 1 mbar
Principle Of Measurement Cold-cathode Pirani combination vacuum gauge (IM inverted magnetron)

Performance Data

Measurement Uncertainty 50 to 1x10-2 mbar ±15%
1x10-2 to 1x10-8 mbar ±30%
Power consumption Max String 4W
Pressure Measurement Min 1.000 × 10⁻⁷
Pressure Measurement Max 1.000 × 10⁵

Environmental Conditions

Temperature Ambient Operation Max 50.00
Temperature Ambient Storage Max 70.00
Temperature Ambient Operation Min 0.000
Temperature Ambient Storage Min -30.00

Material of Construction

Material Filament Tungsten/Rhenium
Material Body Stainless Steel 1.4404 / 316 L / X2 CrNiMo 17 13 2
Material Exposed to Vacuum Stainless Steel 316L and 304L, Tungsten, Glass, Molybdenum, Trace of Nickel and Nickel iron

Connectivity - Communication Interface

Communication Interface Protocol 1.4 - 8.6 V log linear with pressure PTR 90 RN
Communication Interfaces Customer 0-10 V (analog output - linear)
Connection electrical comms interface connector RJ45 (FCC 68) - Female
Status Indicator LED Light Ring

Operation Conditions - Limitations

Pressure Absolute Inlet Continous Max 1.500 × 10⁵
Pressure Inlet Max Overpressure 1.000 × 10⁶
Temperature Baking Max (Elec. Removed) 150.00
Temperature Baking Max 50.00

Variants

Variant Gauges PTR 90 RNS (linear 0-10V output, setpoint)
Product Title Part Number Price Add to cart
Spare PTR 90 RNS - RJ45 Electronics (Podule) E23LA1A1100 GBP 952.00
Spare Tube PTR 90 RN - DN 40 KF E23L0A3AAA0 GBP 819.00