Skip to content Skip to navigation

Specifications

Connection Vacuum Inlet Flange DN 250 ISO-K
Connection vacuum outlet flange DN 160 ISO-K
Cooling Method Water Cooling
Supply Voltage 3Ph 380-480V 50/60Hz 3Ph 460V 60Hz

RUVAC WH4400 18kW, HD LVO 210

Part Number: 1227440V10

Variant

Explore the range of variants given below to compare the product

General Product Information

Connection vacuum outlet flange DN 160 ISO-K
Connection Vacuum Inlet Flange DN 250 ISO-K
Cooling Method Water Cooling
Dimension Height 0.645
Dimension Length 1.18
Dimension Width 0.419
IP Rating IP55
Supply Frequency 50 Hz
60 Hz
Power Supply Phase 3-Ph
Supply Voltage 3Ph 380-480V 50/60Hz
3Ph 460V 60Hz
Weight 590.00
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.
Connection Inlet / Outlet Flange DN 250 ISO-K | DN 160 ISO-K

Performance Data

Power Consumption Max 800.00
Power Total Rated @50Hz 18500.00
Power Total Rated @60Hz 18500.00

Environmental Conditions

Temperature Ambient Operation Max 40.00
Temperature Ambient Storage Max 60.00
Temperature Ambient Operation Min 10.00
Temperature Ambient Storage Min -10.00

Classification

Dry or Wet Pump Dry
Product Pressure Range Medium Vacuum: 1 mbar - 1·10⁻³ mbar
Rough Vacuum: 1000 mbar - 1 mbar
High / Medium / Rough Vacuum Classification Rough Vacuum Pump
Vacuum Pump Technology Mechanical Booster Pump