Specifications

Connection Inlet Flange DN 160 CF (8")
Connection Outlet Flange DN 25 ISO-KF (NW25)
Cooling Method Air Cooling (convection) Air Cooling (forced - fan) Water Cooling
Power Supply Voltage DC 48V
Power Total Rated 600.00
Pumping Speed Air Nitrogen (@50Hz or max @default setting) 0.680
Pressure Ultimate 1.000 × 10⁻⁸

TURBOVAC 850 i - DN 160 CF UHV

Part Number: 840083V1000

Variant

Explore the range of variants given below to compare the product

Short Description Part Number Variant TMP
840071V1000 TURBOVAC i - frontend 1 (basic)
840071V2000 TURBOVAC i - frontend 2 (Anybus/Fieldbus extention)
840071V3000 TURBOVAC iX - Xtention box controller
840071V3300 TURBOVAC iX - Xtention box controller
840072V1000 TURBOVAC i IND - Industrial version - frontend 1 (basic)
840073V1000 TURBOVAC i(X) UHV - Ultra High Vacuum version - frontend 1 (basic)
840073V2000 TURBOVAC i(X) UHV - Ultra High Vacuum version - frontend 2 (Anybus/Fieldbus extention)
840081V1000 TURBOVAC i - frontend 1 (basic)
840081V2000 TURBOVAC i - frontend 2 (Anybus/Fieldbus extention)
840081V3000 TURBOVAC iX - Xtention box controller
840081V3300 TURBOVAC iX - Xtention box controller
840083V1000 TURBOVAC i(X) UHV - Ultra High Vacuum version - frontend 1 (basic)
840083V2000 TURBOVAC i(X) UHV - Ultra High Vacuum version - frontend 2 (Anybus/Fieldbus extention)

General Product Information

Accessories / Scope of Supply TURBOVAC i pumps come stand-alone - the suitable power supply unit, comms/power cables, and cooling options need to be ordered separately. IND industrial variants come with an equipped water cooling unit and are water cooling only.
Connection Cooling 6x1 mm flexible hose quick connection
1/8" BSPP (G) Female
Connection Outlet Flange DN 25 ISO-KF (NW25)
Connection Inlet Flange DN 160 CF (8")
Cooling Method Air Cooling (convection)
Air Cooling (forced - fan)
Water Cooling
Dimension Height 0.292
Dimension Length 0.266
Dimension Width 0.241
IP Rating IP40
Noise / Sound Level 50.00 db(A)
50.00 db(A)
Power Supply Frequency DC Voltage
Power Supply Voltage DC 48V
Weight 19.60
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.
Connection Inlet / Outlet Flange DN 160 CF (8") | DN 25 ISO-KF (NW25)
Certification of Product CE
UL (61010-1 3rd Edition)
CSA (C22.2 No.61010-1-12)
Connection Purge Gas, Gas Ballast, Vent 1/8" BSPP (or G 1/8") Female
1/8" BSPP (or G 1/8") Female

Environmental Conditions

Temperature Ambient Operation Max 40.00
Temperature Ambient Storage Max 70.00
Temperature Ambient Operation Min 5.00
Temperature Ambient Storage Min -15.00
Magnetic Field Resistance Max (covering worst direction - come and consult us for more details) 9.000 × 10⁻³ T

Classification

Classification Dry or Wet Pump Dry
Classification Product Pressure Range High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
Ultra High Vacuum: 1·10⁻⁷ - 1·10⁻¹¹ mbar
Classification High / Medium / Rough Vacuum pump High Vacuum Pump
Classification Vacuum Pump Technology Turbomolecular Pump - hybrid bearing oil free

Performance Data

Compression Ratio Air Nitrogen 1.000 × 10¹³
Compression Ratio Helium 5.000 × 10⁹
Compression Ratio Hydrogen 3.000 × 10⁸
Power Total Rated 600.00
Pressure Ultimate 1.000 × 10⁻⁸
Pumping Speed Air Nitrogen (@50Hz or max @default setting) 0.680
Pumping Speed Argon 0.610
Pumping Speed Helium 0.790
Pumping Speed Hydrogen 0.710
Ramp Up Time 150.00
Nominal rotational speed 820.00
Performance Comment The compression of a TMP is a value describing how good the design can compress a gas type at special conditions. Compression data is measured only using the CF flange variants. The values are stated for all family members. For some pump classes we are stating different pumping speeds ISO > CF flange as small differences in geometry influence their performance leading to a difference >5%.
Gas Throughput Air Nitrogen Max 0.400
Gas Throughput Helium Max 0.700
Gas Throughput Max Hydrogen 1.70
Gas Throughput Argon Max 0.260
Pressure Backing Max 1200.00
Compression Ratio Argon 1.000 × 10¹³

Connectivity - Communication Interface

Communication Interface Protocol USS Universal Serial Interface Protocol
Communication Interfaces Customer RS485 (serial)
REMOTE X1 (Parallel I/O)
USB
Connection Electrical Comms Interface Connector DSUB 9-PIN - Male
DSUB HD 15-PIN - Female (high density)
USB type B - Female

Variants

Installation Orientation Any orientation
Variant TMP TURBOVAC i(X) UHV - Ultra High Vacuum version - frontend 1 (basic)

Operation Conditions - Limitations

Flow Cooling Water Min 1.667 × 10⁻⁵
Temperature Cooling Water Max 35.00
Temperature Cooling Water Min 15.00
Flow Cooling Water Max 3.000 × 10⁻⁵
Pressure Permissible Supply Cooling Water - Min and Max 4.000 × 10⁵
4.000 × 10⁵
Product Title Part Number Price Add to cart
Communication cable - USB cable 2.0 type A/B 1.8m 800110V0108 GBP 21.80
Start-stop switch for TURBOVAC i/iX 800110V0021 GBP 88.50
Vent valve - 24V DC - 1/8" BSPP (G) Male (450mm) 800120V0012 GBP 717.00
Inlet screen coarse - DN 160 CF 800132V0031 GBP 143.00
Splinter guard - DN 160 CF fine 800132V0032 GBP 143.00
Mounting kit TURBOVAC - DN 160 CF 800134V0031 GBP 306.00
Air Cooling Unit - TURBOVAC 850 - 950i radial 800136V0011 GBP 432.00
Cable Power DC - TURBOVACi 850-1450 Supply 48V DC open end 1m (external power supply) 800096V0101 GBP 224.00
Cable Power DC - TURBOVACi 850-1450 Supply 48V DC open end 3m (external power supply) 800096V0301 GBP 238.00
Cable Power DC - TURBOVACi 850 - 1450 Supply 48V DC open end 5m (external power supply) 800096V0501 GBP 253.00
Water Cooling Unit - TURBOVACi 1/4" BSPP (G) -- tube - (850/950/1350/1450) 800135V0007 GBP 321.00
TURBO.CONTROL i 800100V0004 GBP 1,355.00
Connector Accessory Y-connector - TURBOVAC i / TURBOLAB M8 800110V0020 GBP 65.10
Power Failure Vent Valve - 24V DC - 1/8" BSPP (G) Male (450mm) 800120V0022 GBP 689.00
Cable Power DC - Extension cable TURBOVACi 850-1450 3m 48V DC (TP800 only) 800096V0303 GBP 269.00
Cable Power DC - Extension cable TURBOVACi 850-1450 5m 48V DC (TP800 only) 800096V0503 GBP 293.00
Mounting Kit TP800 TURBOVACi 850-1450 (washers and bolts enclosed) 800100V0110 GBP 164.00
Cable Accessory - TURBOVAC i / TURBOLAB M8-M8 2m 800110V0016 GBP 133.00
Purge Valve - EM 24V DC - 1/8" BSPP (G) Male (450mm) 800120V0013 GBP 764.00
TURBO.POWER 800 (IP54) 800100V0010 GBP 1,255.00
Air Gas Filter - TURBOVAC 1/8" BSPP (G) Male 800110V0022 GBP 73.50
Cable Accessory - TURBOVAC i / TURBOLAB M8-M8 5m 800103V0003 GBP 82.70
THERMOVAC TTR 91 RN - DN 16 ISO-KF 21L1011100 GBP 457.00
PENNINGVAC PTR 90 RN - DN 40 CF 23L0041100 GBP 1,591.00